第13回
ポスト処理ファーズドアレイUTによる鋳鋼内欠陥のサイジング精度向上
著者:
山本 摂,Setsu YAMAMOTO,千星 淳,Jun SEMBOSHI,菅原 あずさ,Azusa SUGAWARA,土橋 健太郎,Kentaro TSUCHIHASHI,安達 弘幸,Hiroyuki ADACHI,日隈 幸治,Koji HIGUMA
発刊日:
公開日:
キーワードタグ:
Phased array ultrasonic testing (PAUT) has performed an important role for plant maintenances. However, many parts of cast austenitic stainless steels are difficult to be inspected by UT owing to their noises from large grains. We have been noticing that depending on the PAUT conditions, (e.g. incident angles and focal depths), the tendency of echoes from defects are different from that of grain noises. Thus we have developed new PAUT system which can analyze the tendency of echoes from comprehensive PA...
英字タイトル:
Sizing Accuracy Improvement of Defects in Cast Austenitic Stainless Steel Using Post Processing Phased Array UT
第13回
原子炉圧力容器の給水ノズルコーナーに対する渦電流探傷技術の開発
著者:
神長 貴幸,Takayuki KAMINAGA,吉川 祐明,Hiroaki KIKKAWA,山田 浩二,Koji YAMADA,平崎 孝幸,Takayuki HIRASAKI,西岡 朋美,Tomomi NISHIOKA,首藤 浩丈,Hirotake SYUTOU,齋藤 康二,Koji SAITO,東海林 一,Hajime SHOHJI,江原 和也,Kazuya EHARA,土橋 健太郎,Kentaro TSUCHIHASHI
発刊日:
公開日:
キーワードタグ:
It is necessary to confirm whether the feed water nozzle inside corner has crack by eddy current testing, to enable long-term operation of a plant. Therefore, we performed eddy current testing using various types of specimen to collect basic data (probability and length measurement accuracy) of the eddy current testing methods, complying with JEAG4217. As a result, eddy current testing was effective for the inspection of feed water nozzle inside corner. ...
英字タイトル:
Eddy current testing technique for feed water nozzle inside corner of nuclear reactor pressure vessel
第14回
大型素子アレイプローブを用いたフェーズドアレイ UT リニアスキャンの分解能向上
著者:
山本 摂,Setsu YAMAMOTO,菅原 あずさ,Azusa SUGAWARA,千星 淳,Jun SEMBOSHI,落合 誠,Makoto OCHIAI,土橋 健太郎,Kentaro TSUCHIHASHI,山本 智,Satoshi YAMAMOTO
発刊日:
公開日:
キーワードタグ:
山本 智 Satoshi YAMAMOTO Non-Member (Times New Roman 10pt) should be about 150 words. Recently, an application target of the phased array ultrasonic testing (PAUT) has been extended. For the inspection of CASS, low frequency (less than 1 MHz) array probe is required. Low frequency array probe are usually constructed by large pitch element. In the case of linear scanning, the low frequency array probe could not obtain enough number of sound beams which construct a precise B-Scope image owing to non-dense arra...
英字タイトル:
Accuracy improvement of the linear scanning phased array UT with a large element array probe